SampleTypeCode | SampleTypeDescr | BactiPos | A certifiied reference material containing bacteria targeted for analysis |
BottleBlank | An analyte-free water sample prepared in the lab and used to evaluate potential contamination due to sample container or lab cleaning methods. |
CCB | Continuous Calibration Blank |
CCS | Continuing Calibration Standard |
CCV | Continuous Calibration Verification |
CHK | Lab Check Sample |
CNDL | Negative Control Dilution |
CNEG | Clean water or sediment free of contaminants or test material used to determine test acceptability and as a baseline for gauging adverse effects among animals exposed to treatments. |
CNpH | Clean water, sediment or test material free of contaminants that has been altered to reflect the pH of a particular sample. CNpH are prepared to control for the potential effects of the pH on test organisms |
CNSL | Clean water, sediment or test material free of contaminants that has been altered to reflect the salinity or conductivity of a particular sample. CNSL are prepared to control for the potential effects of the salinity or conductivity on test organisms |
CompBLDup | Composite Blind Duplicate |
Composite | Used for Tissue Samples regardless of whether composite has one or more than one organism |
CPOS | Positive Control |
CRM | Homogeneous matrix that closely matches samples being analyzed with certified concentrations of analytes of interest purchased by the laboratory. |
DIBlank | performed to check contamination in DI Water water not from analyzing lab |
Epiphyte | Used for the epiphyte fraction of an algae bioassessment taxonomy sample. |
EquipBlank | Clean water pumped through new equipment, cleaned equipment after contamination, equipment for non-surface water, new lot of filters (metals), preserved (if appl.) and analyzed.Sample comment required:Type of equipment, where taken (lab or field) |
ERM | Sample of known analyte concentrations created by an external agency and sent to the analyzing laboratory for analysis as a standard material |
FieldBlank | Clean water taken to field, transferred to container, preserved (if appropriate) and treated same as corresponding sample type during the sampling event. |
FieldBLBlank | Clean water taken to field, transferred to container, preserved (if appropriate) and treated same as corresponding sample type during the sampling event, submitted blind to the laboratory |
FieldBLDup_Grab | Field Blind Duplicate of a grab sample |
FieldBLDup_Int | Field Blind Duplicate of an integrated sample |
FieldBLDup_Split | Field Blind Duplicate sample collected and then split to two separate jars |
FieldExpos | A QA sample collected and left in the field for an extended period of time to test for changes in analyte concentration. Sample comment required for duration of exposure time |
FieldSp | Environmental or blank sample spiked with analytes of interest, created by the sampling crew or by submitting agency for its subcontracted lab |
FieldSplit | Single sample collected and then split to two separate jars |
FilterBlank | Clean water that is filtered in the same manner and through the same filter apparatus used for the sample. |
Grab | Single sample |
IBLANK | Initial Blank at start of batch |
ICB | Initial Calibration Blank |
ICM | Intercalibration Material Water, Tissue, Sediment |
ICV | Initial Calibration Verification |
Integrated | Combined from multiple samples |
IntegratedSplit | Combined from multiple collections into one sample then split into separate subsamples |
LabBlank | Processed through the entire analytical procedure in a manner identical to the samples. |
LCS | Aliquot of a reference matrix fortified (spiked) with known quantities of specific compounds and subjected to the entire analytical procedure to determine the accuracy of the method by measuring recovery |
Macroalgae | Used for the macroalgal fraction of an algae bioassessment taxonomy sample. |
Microalgae | Used for the microalgal fraction of an algae bioassessment taxonomy sample. |
MS1 | Matrix spike and matrix spike duplicate |
MS2 | Matrix spike for Field Duplicate |
MS3 | MS performed on a field triplicate |
MSBLBlank | Matrix spike for Blind Field Blank |
MSBLDup | Matrix spike for FieldBlind Duplicate |
NEC | Control for DNA extraction |
Not Recorded | Not recorded |
PCR_Blank | PCR Blank. PCR reagents with DNA-free water used to check for contamination in PCR analyses. |
PCR_Extraction_Blank | PCR Extraction Blank. DNA-free water is filtered and extracted with reagents to check for contamination in the filtration/extraction process. |
PDS | Post Digestion Spike |
PreservBlank | Performed to check preservative prior to mixing with sample |
Qualitative | Used for qualitative sampling where quantitative sample information is not expected |
RFST | Reference Stations have similar physical characteristics to monitoring stations, but contain low or non-detectable concentrations of contaminants. Used for statistical & biological comparisons to determine magnitude of toxicity in monitoring stations. |
SituExpos | Organisms exposed for the period of time of the analysis in a collection device deployed in situ. Sample comment required for duration of exposure time |
Trash | TrashAssessment |
TravelBlank | Clean water transported to site, handled like sample (never opened), and returned to lab for analysis. |